GENERAL SAFETY CONDITIONS IMPORTANT SAFETY INSTRUCTIONS FOR USE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE
- Before using the device, read the instruction manual and follow the instructions contained therein. The manufacturer is not responsible for damage caused by using the device contrary to its intended use or improper operation.
- The device is for domestic use only. Do not use for other purposes incompatible with its intended use.
- The device should be connected only to a 220-240V ~50-60 Hz grounded outlet. In order to increase the safety of use, multiple electrical appliances should not be plugged into a single circuit at the same time.
- Take special care when using the device when children are around. Do not allow children to play with the appliance. Do not allow children or persons\ unfamiliar with the appliance to use it.
- WARNING: This equipment may be used by children over 8 years of age and persons with limited physical, sensory or mental ability, or persons without experience or familiarity with the equipment, if it is under the supervision of a person responsible for their safety or they have been given instructions on the safe use of the equipment and are aware of the dangers associated with its use. Children should not play with the equipment. Cleaning and maintenance of the equipment should not be performed by children unless they are over 8 years of age, and these activities are performed under supervision.
- Always after use, remove the plug from the power outlet by holding the outlet with your hand. DO NOT pull on the power cord.
- Do not immerse the cable, plug, or the entire device in water or other liquid. Do not expose the unit to weather conditions (rain, sun, etc.) or use it in high humidity conditions (bathrooms, humid motor homes).
- Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialized repair facility to avoid danger.
- Do not use the device with a damaged power cord or if it has been dropped or damaged in any other way, or is not working properly. Do not repair the device yourself, as there is a risk of electric shock. Take the damaged device to a competent service center for inspection or repair. All repairs may be carried out only by authorized service centers. Improper repair may cause danger to the user.
- Do not use the device near flammable materials.
- The power cord must not touch hot surfaces.
- Do not leave the device or the power supply to the outlet unattended.
- To provide additional protection, it is advisable to install in an electrical circuit, a residual current device (RCD) with a rated residual current not exceeding 30 mA. In this regard, consult a specialist electrician.
- Do not let the motor part of the device get wet.
- Do not use the device outside the home; use it only indoors.
- Do not use the vacuum cleaner to collect flammable substances (such as fuel, solvents).
- Do not vacuum sharp-edged objects (such as glass shards).
- Do not point the suction tube of the vacuum cleaner towards other people or animals.
- Vacuum only dry surfaces.
- Use only accessories designed for this device.
- Take special care when vacuuming stairs, and take care of your safety.
- Do not block any ventilation holes.
- Do not run the vacuum cleaner without the filter in place.
- Do not pull the vacuum cleaner by the hose.
- Be careful that the power ADLER AD 7065 Cyclone Vacuum Cleaner cord is not cut by the door or stuck. Pay attention to the length of the power cord when moving the vacuum cleaner. Rapidly pulling the vacuum cleaner with the cable stretched taut can cause damage to the cable.
- Do not vacuum dust and construction debris; the residue of such debris will.
Immediately void the warranty. - Do not leave the device unattended during operation.
- Always unplug the unit if left unattended, and before folding, unfolding, or cleaning.
- Always turn off the device with the button before unplugging.
CAUTION:
- The vacuum cleaner is designed for dry cleaning rooms.
- The vacuum cleaner is not designed to collect water or other liquids; do not use it to collect smoldering or burning cigarettes or ashes.
- Do not use the vacuum cleaner to collect dust from plaster, concrete, flour, or ashes.
- Remove sharp objects from the floor before cleaning to prevent damage to the hose. If the suction power of the vacuum cleaner drops sharply during cleaning, immediately turn it off, unplug it from the outlet, and check the telescopic tube (4) or flexible hose (7) for patency. Remove the obstruction, after which you can resume cleaning.
PRODUCT DESCRIPTION: AD7065 vacuum cleaner
- floor/carpet brush
- floor/carpet switch
- telescopic tube button
- Telescopic extension tube
- flexible hose holder
- manual adjustment of suction power
- flexible hose
- flexible hose end
- hose end locks
- air inlet
- Complete dust container.
- carrying handle
- dust container lock button
- power cord retraction button
- parking position hanger
- power button
- suction power knob
- outlet filter cover
- HEPA 13 filter
- Lower the dust container cover
- Locking device of the lower dust container cover
- Dust container housing
- Dust container upper cover
- Cyclone filter
- inlet filter
- Sponge filter
- Accessory holder
- Crevice tool
- Upholstery brush 2-in-1
- Mini-turbo brush
- parquet brush
BEFORE FIRST USE
After transporting or storing the device in sub-zero temperatures, unpack it and wait at least 3 hours before using it.
USE OF ACCESSORIES:
- Floor/carpet brush (1): When using the brush (1), set the switch (2) to the desired “FLOOR/carpet” position.
- Crevice nozzle (28): Use the crevice nozzle (28) to clean radiators, crevices, spaces between couch cushions, and the like.
- Upholstery brush (29): It is designed to clean fabric surfaces of upholstered furniture and to collect dust from the surface of furniture, while the presence of fibers on the brush (29) prevents damage to the polished surface of furniture. When working, put the brush on the cap (29).
- Mini-turbo brush (30): It is designed for cleaning fabric surfaces in hard-to-reach corners, such as the interior of a car.
- Parquet brush (31): It is designed for cleaning wooden surfaces.
VACUUM CLEANER ASSEMBLY
Inserting and removing the flexible hose (7).
Insert the end of the flexible hose (7) (8) into the air inlet (10) until the latches (9) snap into place. To remove the flexible hose (7), push in the latches (9) and disconnect the end (8) from the air inlet (10).
Attaching the telescopic tube (4) and accessories
Attach the telescopic extension tube (4) to the flexible hose holder (5). Extend the lower part of the tube (4) to the required length after pressing the button (3). Select the necessary accessories:
- floor/carpet brush (1),
- crevice nozzle (28)
- 2-in-1 upholstery brush (29)
- mini-turbo brush (30)
- parquet brush (31) and then attach it to the telescoping extension tube (4).
The crevice nozzle (28) and the 2-in-1 upholstery brush (29) can be attached to the flexible hose holder (5).
USING THE VACUUM CLEANER
- the dust container (11) is equipped with a cyclone filter (24), which centrifuges debris and dust from the sucked air, while the inlet filter (25) and sponge filter (26) trap the finest dust particles.
NOTE: Make sure that the inlet filter (25) and sponge filter (26) are always clean, as the overall performance of the vacuum cleaner depends on this. - Before turning on and using the vacuum cleaner, make sure that the cyclone filter (24), filters (25, 26), dust container (11), and HEPA exhaust filter (19) are properly installed.
- Remove the power plug and unroll the power cord to the required length, and plug the power plug into the power outlet.
- The yellow marking on the power cord indicates the maximum length of the cord. Do not extend the power cord further than the red mark.
- Press the power button (16) to turn on the vacuum cleaner.
- While cleaning, you can adjust the suction power with the manual suction power regulator (6) on the flexible hose handle (5) or by turning the suction power adjustment knob (17).
- When you have finished cleaning, turn off the vacuum cleaner by pressing the power button (16) and unplugging it.
- To retract the power cord, press the button (14); hold the cord with your hand while retracting it.
- If you need to take a break during cleaning, turn off the vacuum cleaner by pressing the power button (16) and attach the brush (1) to the parking position hanger (15).
NOTE: Before changing accessories or cleaning the dust container (11), turn off the vacuum cleaner by pressing the power button (16) and unplugging it.
CLEANING AND MAINTENANCE
Cleaning the dust container (11):
- It is recommended to remove debris and dust from the dust container (11) after each cleaning of the room.
- Turn off the vacuum cleaner by pressing the power button (16) again and unplugging it.
- Hold the dust container handle, press the lock (13), and remove the entire dust container (11) (Fig. II.1).
- Place the entire dust container (11) over the dust garbage can.
- Press the clamp (21), and then the lower cover (20) will drop down, releasing dust and fine debris (Fig. II.2).
- Remove accumulated dust and debris from the dust garbage can (11), if it still does not fall into the dust garbage can.
- Close the lower cover (20).
- Install the entire dust bin (11) back in place and make sure the dust bin (11) is properly fastened.
Cleaning the filters (24), (25), (26).
NOTE! Make sure that the cyclone filter (24), filters (25, 26), and dust container housing (22) are COMPLETELY dry before ADLER AD 7065 Cyclone Vacuum Cleaner assembling and reinstalling the entire dust container (11) in its place.
The cyclone filter (24) and filters (25, 26) are installed in the dust bin (11). Preliminarily remove dust and debris from the dust container (11) as described above.
- Turn the cover (23) counterclockwise and remove it. Remove the sponge filter (26), take out the inlet filter (25), and the cyclone filter (24).
- Clean the cyclone filter (24) of dust and debris. Wash the cyclone filter (24) under a stream of warm water and dry completely.
- Wash the inlet filter (25) and sponge filter (26) under a stream of warm water and dry. Dry the filter (25, 26) completely.
- Do not dry any filter with a hair dryer or similar device. Do not wash parts in a dishwasher.
- Wash the dust container housing (22), wipe it, and dry it.
- Insert the cyclone filter (24) into the dust container housing (22).
- Insert the inlet filter (25) and sponge filter (26) into the cyclone filter (24).
- Replace the cover (23) and turn it clockwise as far as it will go.
- Install the completely assembled dust container (11) back into place, making sure that the entire dust container (11) is properly attached.
Cleaning the HEPA 13 exhaust filter (19).
Turn off the vacuum cleaner and remove the power cord plug from the power outlet.
- Remove the outlet filter cover (18) by turning it clockwise, and remove the HEPA outlet filter (19) (Fig. II.3).
- Wash the HEPA 13 outlet filter (19) and cover (18) under a stream of lukewarm water. Do not wash the HEPA outlet filter 13 (19) and cover (18) in the dishwasher.
- Dry HEPA outlet filter 13 (19) and cover (18). Do not dry HEPA filter 13 (19) with a hair dryer or similar device.
- Install the HEPA outlet filter 13 (19) back into place.
- Put the cover (18) back in place, turn the cover (18) counterclockwise until it stops.
Vacuum cleaner housing
- Clean the vacuum cleaner housing with a soft, slightly dampened cloth, then wipe dry. Be careful that no liquid gets into the vacuum cleaner body.
- Do not use solvents or abrasives to clean the vacuum cleaner body and accessories.
- Do not immerse the vacuum cleaner body, power cord, or plug in water or other liquids.
PROTECTION AGAINST OVERHEATING
- If the electric motor ADLER AD 7065 Cyclone Vacuum Cleaner overheats during operation, the overheat protection system will be activated, and the device will shut down automatically.
- In this case, press the power button (16) and unplug the device.
- Wait 30-40 minutes for the vacuum cleaner to cool down and turn it on again. The cooling time may differ from the specified value depending on the temperature in the room.
- If the vacuum cleaner does not turn on, it may be due to another malfunction. In this case, contact the dealer’s service center indicated on the purchase receipt.
STORAGE
- Before putting the vacuum cleaner away for a long period of time, clean the vacuum cleaner body, dust container outside and inside, cyclone filter (24), filters (25, 26), and HEPA exhaust filter (19).
- To make it easier to store the vacuum cleaner, use the parking position hanger (16) to attach the tube(4) and hose (7).
- Attach the accessory holder (27) to mount the crevice nozzle (28) and 2-in-1 upholstery brush (29).Store
- The vacuum cleaner in a dry and cool place, out of the reach of children and people with disabilities. The complete set consists of:
- Vacuum cleaner with installed dust container and filters
- flexible hose
- Telescopic extension tube
- floor/carpet brush
- crevice tool
- Upholstery brush 2-in-1
- Mini-TURBO brush
- Parquet brush
- crevice nozzle
- instruction manual
- Hanger for accessories
Technical Specifications
- Power supply: 220-240V~ 50-60Hz
- Rated power: 700W
- Suction power: 170W
- Dust container capacity: 1.6 liters
For the sake of the environment
Cardboard packaging and polyethylene (PE) bags should be disposed of in the appropriate containers for separate collection of ADLER AD 7065 Cyclone Vacuum Cleaner municipal waste according to their description. If there are batteries in the device, remove them and separately return them to a collection and storage point. Return the used device to a suitable collection and storage facility, as the hazardous substances in it may pose a threat to health and the environment.
The marking on the product indicates that the device should not be disposed of in the container with municipal waste. Waste electrical equipment is waste that contains substances harmful to humans, animals, and the environment.
These substances can ADLER AD 7065 Cyclone Vacuum Cleaner lead to contamination of the soil, water, or air, and through this, they can enter the human body and lead to numerous health ailments, such as vision, hearing, and speech disorders. They can also damage the kidneys, liver, and heart, and cause skin diseases. Harmful substances can also have adverse effects on the respiratory and reproductive systems and lead to cancerous changes. Consumption of plants growing on the complained-of soils, and products made from them, may risk the above-mentioned health effects. Do not dispose of the device in the municipal waste container!! Service: If you wish to purchase spare parts or report any complaints, please contact directly with the seller who issued the receipt directly.
FAQs
Q1: What type of vacuum cleaner is the ADLER AD 7065?
The AD 7065 is a cyclone bagless hoover cleaner that effectively removes dust and debris with cyclonic technology, offering powerful suction without the need for frequent filter replacement.
Q2: What surfaces can it clean?
The AD 7065 works well with upholstery, carpets, rugs, and hard floors. For certain surfaces, like as car interiors or drapes, use the provided attachments.
Q3: How do I empty the dust container?
Carefully remove the dust bin by pressing the release button. Before reattaching, empty the contents into a trash can, rinse with water if needed, and make sure it is completely dry.
Q4: Does it come with HEPA filtration?
Indeed. The AD 7065 is perfect for homes with allergy sufferers because it has a HEPA filter that captures allergens, pollen, and tiny dust.
Q5: How do I clean the filters?
Take out the HEPA and main filters. Rinse the main filter with water and let it to air dry. Some versions allow rinsing if specified in the handbook, although the HEPA filter can also be lightly tapped or vacuumed.
Q6: What is the power rating of the vacuum cleaner?
Operating at 700–800W, the AD 7065 offers powerful suction while using little energy for everyday cleaning.
Q7: Can it handle pet hair effectively?
Indeed. It can remove pet hair from furniture and carpets because to its powerful suction and cyclone system, especially when the special brush attachment is used.
Q8: How do I maintain optimal suction?
Empty the dust container on a regular basis, inspect the hose and attachments for obstructions, and clean or replace the filters as advised.