    Home » Labnet S2030-LS-B Orbit LS Low Speed Shaker User Manual
    Labnet

    Labnet S2030-LS-B Orbit LS Low Speed Shaker User Manual

    By Gabriel SmithOctober 31, 2025Updated:January 10, 2026No Comments7 Mins Read
    Facebook Twitter Pinterest LinkedIn Tumblr WhatsApp Telegram Email
    Labnet-S2030-LS-B-Orbit-LS-Low-Speed-Shaker-featured
    Share
    Facebook Twitter LinkedIn Pinterest Email

    Labnet-Logo

    Labnet S2030-LS-B Orbit LS Low Speed Shaker User Manual

    Labnet-S2030-LS-B-Orbit-LS-Low-Speed-Shaker-product

    Introduction

    Congratulations on purchasing your Labnet Orbit™ LS Low Speed Orbital Shaker. A large shaker orbit and low speed make this orbital shaker useful for staining and destaining gels, washing blots, and general mixing. The shaker is supplied with a 29.5 x 29.5 cm stainless steel flat platform and a non-slip rubber mat to keep plates, dishes, and other sample containers in place. Safe for use in temperature-controlled environments, the small profile of this shaker makes it ideal for use in incubators such as the Labnet 311 and 611 series.

    Unpacking

    The Labnet Orbit LS Low Speed Orbital Shaker includes the following components:

    • Labnet Orbit LS Low Speed Orbital Shaker
    • Flat platform (29.5 x 29.5 cm)
    • Instruction Manual

    Safety Information

    Do not shake flammable or explosive samples.

    • Do not use the shaker near water sources. Be sure that water doesn’t get on the device, especially during the cleaning procedures.
    • Do not expose the shaker to aggressive vapors (e.g., organic solvents).
    • Do not insert objects into the shaker (such as a screwdriver or metal rods).
    • Never operate the shaker without the platform securely attached.
    • Hazardous samples should be shaken only in appropriate containment vessels.

    Symbols and Conventions

    The following chart is an illustrated glossary of the symbols that may be used in this manual or on the product.

    • Indicates the presence of a potential hazard which could result in electrical shock.
    • Identifies a Protective Earth (PE) terminal, which is provided for connection of the supply system’s protective earth (green or green/yellow) conductor.
    • Do not put your fingers between the platform and the housing. Danger of mechanical injury

    Installation

    Device Placement

    When selecting the right place for the device, please consider the following:

    • Put the device on a smooth, horizontal, and stable surface.
    • Leave enough space beyond the device for normal air circulation (6 in./15 cm minimum).
    • Leave enough space around the device for easy access and maintenance.
    • Avoid locations subject to shocks and vibrations.
    • Avoid locations subject to frequent power fluctuations or power losses. It may affect shaker performance.

    NOTE: There has to be easy access to the shaker control panel and main plug in case of emergency.

    Attaching the Power Cord

    First, connect the main power cord to the shaker. Then, connect the plug end of the cord to a grounded wall socket. Avoid lines on which powerful electric motors, refrigerators, and similar devices are connected.

    • Be careful when you plug the cord into a grounded wall socket.
    • Do not touch the plug with wet hands.
    • Do not pull the plug by the cord.

    Operating Instructions

    Control Panel

    Labnet-S2030-LS-B-Orbit-LS-Low-Speed-Shaker-figure-1

    1. POWER switch: Turns the shaker ON (power switch illuminates) or OFF.
    2. SPEED knob: Sets the shaker speed.
    3. TIME knob: Sets the timed operation.
    4. HOLD yellow signal light: Illuminates when the shaker is set to HOLD (continuous operation).
    5. START/STOP button: START or STOP the shaking operation.
    6. RUN green signal light: Illuminates when the shaker is running.

    Maintenance and Cleaning

    • No routine maintenance or lubrication is required.
    • It is recommended that the shaker be kept clean to ensure long trouble-free operation.
    • The outside housing can be cleaned with a soft, damp cloth when needed.
    • Do not use any aggressive or abrasive cleaners (acetone,   nitro, polish, etc.).
    • This may permanently damage the shaker finish.

    Specifications

    Shaker orbit0.75 in. (19 mm)
    Timer20 to 120 min. in 10 min. step, HOLD function
    Maximum load11 lbs. (5 kg)
    Dimensions (W x L x H)11.6 x 13.4 x 6.3 in. (29.5 x 34 x 16 cm)
    Platform dimensions (W x L)11.6 x 11.6 in.  (29.5 x 29.5 cm) useable area
    Weight14.6 lbs. (6.6 kg)
    Electrical

    120V

    230V

    120V ±10%, 50/60Hz, 0.3A

    230V ±10%, 50/60Hz, 0.15A

    Fuse2 x 1A
    Operation conditions4°C to 65°C, up to 85% RH, non-condensing

    Troubleshooting

    Should you have a question about the operation of the Labnet Orbit™ LS Low Speed Orbital Shaker or if service is required, contact Customer Service. Do not send in a unit for service without first calling to obtain a repair authorization number. Should the unit require service return, it should be properly packaged to avoid damage. Any damage resulting from improper packaging shall be the responsibility of the user.

    The power switch doesn’t illuminate when turned on. Check the connection to the main power supply.
     Check the fuses.
     Call for the authorized service.
    The shaker doesn’t start when you press the START/STOP button. Check the connection to the main power supply.
     Check the fuses.
     Call for authorized service.

    Accessories

    S2031-12DStacked platforms (29.5 x 29.5 cm)2
    E2110-BBSBlot box, 9.1 x 6.6 cm, 3-50 mL capacity for mini protein gels10
    E2110-BBLBlot box, 11.7 x 8.9 cm, 6-10 mL capacity for larger mini protein gels10

    Limited Warranty

    Corning Incorporated (Corning) warrants that this product Labnet S2030-LS-B Orbit LS Low Speed Shaker will be free from defects in material and workmanship for a period of one (1) year from the date of purchase. Corning’s sole obligation shall be to repair or replace, at its option, any product or part thereof that proves defective in material or workmanship within the warranty period, provided the purchaser notifies Corning of any such defect. Corning is not liable for any incidental or consequential damages, commercial loss, or any other damages from the use of this product.

    Corning’s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions. Corning may elect for on-site service for larger equipment. Some states do not alllimitationsion on the length of implied warranties or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights. You may have other rights that vary from state to state. No individual may accept for, or on behalf of Corning, any other obligation of liability, or extend the period of this warranty.

    Warranty/Disclaimer

    Unless otherwise specified, all products are for research use or general laboratory use only.* Not intended for use in diagnostic or therapeutic procedures. Not for use in humans. Corning Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications. *For a listing of US medical devices, regulatory classifications, or specific information on claims, visit www.corning.com/resources.

    Equipment Disposal

    According to Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE), this product is marked with the crossed-out wheeled bin and must not be disposed of with domestic waste. Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment (WEEE) provided with the products and available at www.corning.com/weee.

    Customer Service

    • Website: www.labnetlink.com.
    • Visit: www.corning.com/lifesciencs
    • Visit: www.corning.com/resources
    • USA/Canada: 1.800.492.1110
    • Others: +1.978.442.2200
    • North America: 978.442.2200
    • Australia/New Zealand: 61 427286832

    FAQs

    What applications is the Labnet Orbit LS Low Speed Shaker best suited for?

    For delicate mixing jobs requiring slow, steady orbital shaking, like cell culture incubation, hybridisation, staining techniques, and sample dissolution, the S2030-LS-B is perfect.

    What is the shaking speed range of this shaker?

    It can precisely handle fragile samples because it runs in the low speed range of 20 to 200 RPM.

    What is the shaking orbit diameter?

    The shaker’s 19 mm orbit allows for steady and even agitation.

    What is the maximum load capacity of the shaker platform?

    When in use, the shaker can securely accommodate up to 7 kg (15.4 lbs) of labware.

    How is the shaking speed controlled?

    A digital control panel with user-friendly buttons and an LED display allows for precise speed setting.

    Is the platform removable for cleaning?

    Indeed, the platform is easily detachable for comprehensive maintenance and cleaning.

    Labnet S2030-LS-B Orbit LS Low Speed Shaker installation guide Labnet S2030-LS-B Orbit LS Low Speed Shaker maintenance guide Labnet S2030-LS-B Orbit LS Low Speed Shaker manual Labnet S2030-LS-B Orbit LS Low Speed Shaker operation manual Labnet S2030-LS-B Orbit LS Low Speed Shaker user manual OnyxGuides Manual User Manual
    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Gabriel Smith

      Related Posts

      Sony ILCE-6700 Interchangeable Lens Digital Camera User Guide

      December 7, 2025

      Bose MA12 Panaray Modular Line Array Loudspeaker User Guide

      December 4, 2025

      Bowers & Wilkins Px8 Wireless Headphones User Manual

      December 4, 2025

      Sonos Arc Black Voice Control Ultra Soundbar User Manual

      December 4, 2025

      JANAM GT1 Self Mobile Entry Head Unit Instruction Manual

      December 4, 2025

      Ronix 1250 Carpet Vacuum Cleaner Instruction Manual

      December 4, 2025
      Add A Comment

      Comments are closed.

      Don't Miss
      DJI

      DJI Neo 4K UHD Camera QuickShots Mini Drone User Manual

      February 10, 2026

      DJI Neo 4K UHD Camera QuickShots Mini Drone Overview Forward-Facing LiDAR [1] Omnidirectional Vision…

      Marshall CV506-H12 Miniature High-Speed Camera User Guide

      February 9, 2026

      Marshall V-702W-12G-V2 Rack Mount Monitor User Guide

      February 9, 2026

      Makita VC2211M Wet & Dry Vacuum Cleaner Instruction Manual

      February 8, 2026
      Stay In Touch
      • Facebook
      • Twitter
      • Pinterest
      • Instagram
      • YouTube
      • Vimeo

      Subscribe to Updates

      Subscribe to Updates

      Follow us

      Facebook X-twitter Instagram Pinterest

      © 2025 All rights reserved Onyx Guide.