    Honeywell

    Honeywell TC09PEU Portable Evaporative Air Cooler User Guide

    Gabriel SmithBy Gabriel SmithSeptember 18, 2025Updated:September 18, 2025No Comments5 Mins Read
    Facebook Twitter Pinterest LinkedIn Tumblr WhatsApp Telegram Email
    Honeywell-TC09PEU-Portable-Evaporative-Air-Cooler-featred
    Share
    Facebook Twitter LinkedIn Pinterest Email

    Honeywell-logo

    Honeywell TC09PEU Portable Evaporative Air CoolerHoneywell-TC09PEU-Portable-Evaporative-Air-Cooler-product

    PARTS DESCRIPTIONHoneywell-TC09PEU-Portable-Evaporative-Air-Cooler-figure-1

    1. Control Panel
    2. Louvers
    3. Water Level Indicator
    4. Casters
    5. Water Fill Door
    6. Drain Plug
    7. Side Grill
    8. Honeycomb Cooling Media
    9. Power Cord & Plug

    USE & OPERATION

    CONTROL PANEL Honeywell-TC09PEU-Portable-Evaporative-Air-Cooler-figure-2

    • Power
    • Cool
    • Swing
    • Speed
      1. = Low
      2. = Medium
      3. = High

    FUNCTION BUTTONS 

    POWER

    Press the button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds, the speed will switch to low. To turn the unit off, press the button again.

    COOL

    You must add water before operating the unit in Cool mode. Press the button until it is illuminated on the display screen. The water pump will operate, and you will feel the cooler air after the Honeycomb Cooling Media is completely wet.

    SPEED

    Press the SPEED button repeatedly to change the speed between | – || – |||.

    SWING

    Press the SWING button until it is illuminated on the display. The louvers will begin to move left to right automatically. You can manually adjust the louvers to change vertical air flow.

    REMOTE CONTROL

    • POWER: ON / OFF
    • SPEED:  Low / Medium / High
    • COOL: Evaporative Cooling ON / OFF
    • SWING: Controls the motion of the louvers

    NOTE:

    • The remote control requires a CR2025 (1 x 3V) coin-type or equivalent battery for replacement. Open the battery compartment at the back of the remote control and insert the battery inside. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.

    COOLER LOCATION 

    Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.

    FILLING WITH WATER 

    CAUTION: Unplug the unit from the electrical socket before emptying or refilling the water tank. Open the Water Fill Door located on the back of the unit.

    Manual Tank Refilling:

    The Water Level Indicator is located at the front of the unit. Refill the water tank when the water level is low. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure.

    LOW WATER ALARM 
    • The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the GREEN LED will flash continuously. The unit will automatically pause evaporative cooling.
    • Refill the water tank to deactivate the alarm in cooling mode. First, switch OFF the unit and unplug it from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again.
    • To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan-only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty.

    CLEANING & DRAINING THE WATER TANK 

    Below are instructions on how to clean and maintain your air cooler.

    WARNING: Before cleaning the unit, power OFF the unit and disconnect from the electrical socket.

    • Move the unit to a location where the water can be drained. Remove the cap from the drain plug located at the bottom of the unit. Allow the tank to empty.
    • Refill the water tank with clean water, up to the maximum level, and drain it completely.
    • Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
    • When the product is not in use, store the unit in a dry place out of direct sunlight.
    CLEANING THE HONEYCOMB COOLING MEDIA 
    • The appliance is supplied with a Honeycomb Cooling Media.
    • The Honeycomb Cooling Media are located Honeywell TC09PEU Portable Evaporative Air Cooler inside the Side Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
    • Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill it with fresh water, especially if the tank has not been cleaned in a long time.
    • The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling
    Removing the Honeycomb Cooling Media
    • Remove all the screws from the side grill of the Air  Cooler, and carefully pull out the side grill from the cooler.
    • Rinse the side grill with clean water and let it dry before reinstalling it onto the unit.
    • Carefully pull out the Honeycomb Media from the unit.
    • Replace or clean media with water and a damp cloth as needed.

    Customer Service

    Website:

    Honeywell portable evaporative cooler Honeywell portable room cooler Honeywell TC09PEU air cooler Honeywell TC09PEU personal cooler Honeywell TC09PEU swamp cooler
    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Gabriel Smith

      Related Posts

      Honeywell H115BCS 115 Can Beverage Cooler User Manual

      September 23, 2025

      Honeywell H34WCB 34 Bottle Wine Cooler Instruction Manual

      September 23, 2025

      Honeywell H14WCB 14 Bottle Wine Cooler Instruction Manual

      September 23, 2025

      Honeywell H7CFW 7 Cubic Feet Chest Freezer User Manual

      September 23, 2025

      Honeywell H35CFW 3.5 Cubic Feet Chest Freezer User Manual

      September 23, 2025

      Honeywell H17UFS 17 Cubic Feet Freezer Instruction Manual

      September 23, 2025
      Add A Comment

      Comments are closed.

      Don't Miss
      Insignia

      Insignia NS-IR10BK6 10” Steam Iron Instruction Manual

      September 23, 2025

      Insignia NS-IR10BK6 10” Steam Iron Safety Instructions Only use an iron for its intended use.…

      Insignia NS-GLSBFSCW1 Glass Scale Instruction Manual

      September 23, 2025

      Honeywell H115BCS 115 Can Beverage Cooler User Manual

      September 23, 2025

      Honeywell H34WCB 34 Bottle Wine Cooler Instruction Manual

      September 23, 2025
      Stay In Touch
      • Facebook
      • Twitter
      • Pinterest
      • Instagram
      • YouTube
      • Vimeo

      Subscribe to Updates

      Subscribe to Updates

      Follow Us

      Facebook Twitter Youtube

      © 2025 All rights reserved Onyx Guide.