Ronix 1231 Industrial Vacuum Cleaner

Safety Instructions
Before operating this appliance, please ensure that you read & understand all the instructions that apply to it, as failure to comply with these instructions may result in personal injury to other persons, and also increase the risk of fire or electrical shock. Please ensure that any replacement parts or accessories used with this appliance are correctly and/or securely fitted before use.
- Check before the operation that the local power supply is the same as the specification on the rating label.
- Do not use the machine in a combustible or explosive place, in case the motor spark causes fire.

- Do not jam the air inlet mouth, in case the temperature rises and damages the motor.

- Do not collect combustible and explosive objects such as glowing cigarettes, gasoline, etc.

- Do not collect sharp objects. Do not collect objects that can easily attach to the filter, such as calcareous powder, gesso, and graphite powder.
- Because those will block the ventilation and damage the motor.
- Turn off the machine and remove the plug each time after using or when being repaired.
- Keep the machine away from strong sunlight and high-temperature places in case the plastic is distorted.

- Do not wrest, tramp, or haul the hose in case of making it is damaged.
- The power cord must be replaced by the Ronix service center.
Part List

Product Characteristics
- Vacuum cleaner for wet and dry
- Jacks on the base, easy for depositing accessories
- The blowing function satisfies different requirements
Usage
- Bristle for bookshelves, windows, and bibulous brush for floor and carpet, tables, etc. If you need a vacuum specifically designed for carpets, you may also find the Ronix 1250 Carpet Vacuum Cleaner Manual helpful for understanding carpet-focused cleaning features.

- Crevice nozzle for crevice, corner, etc. Blowing mouth for blowing the dust away in the crevice of the machine

Operation
- Insert the plug into the supply socket.

- Press the switch button, and the machine begins to work.

- You can adjust the airflow by pushing the sliding block up and down.
- «I» stands for turn on
- «o» stands for turn off
Connection
- Insert the hose connector into the air inlet mouth, as shown in the picture, and pull shown in the picture to make sure the connector is tightly fastened.

- Press the connector button as shown in the picture, and pull the connector out when you want to pull the hose connector from the machine.

Accessories
- Plastic hose with adjustable handle,
- Metal telescopic tube,
- Wet & Dry Floor Brush,
- Crevice Nozzle,
- Round Brush,
- Non-woven cloth filter,
- Sponge filter,
- Washable HEPA filter

Maintainance
Cleaning Barrel
After working or when the barrel is full of dust, which causes the suction to decrease considerably, you should cut off the electricity and clean the dust away from the barrel.
- Unfasten the locking knob, lift the top cover.
- Take off the filter bag, clean the dust away in the dust barrel.
- Install the filter bag back and place the top cover.
Cleaning Filter
The filter bag should be washed with clean and warm water when it is covered with dust. If necessary, you can use Litmus less scour to wash.
- Take off the filters

- Wash

- Dry

- Assemble filters

TECHNICAL SPECIFICATIONS
- Model: 1231
- Power: 1400W
- Voltage: 220-240V
- Frequency: 50-60Hz
- Dust Capacity: 30L
- Vacuum Pressure: >20KPA
- Airflow Rate: 1.9m³/min
Environmental Instructions
- Dispose of cardboard packaging and polyethylene (PE) bags in the appropriate containers for separate collection of municipal waste according to their description.
- If there are batteries in the device, remove them and separately return them to the collection and storage facility. Return the used device to a suitable collection and storage facility, as the hazardous substances in it may pose a threat to health and the environment.
- Waste electrical equipment is waste that contains substances harmful to humans, animals, and the environment.
- These substances can lead to contamination of the soil, water, or air, and through this they can get into the human body and lead to numerous health ailments, such a vision, hearing, and speech disorders; they can also lead to kidney, liver, and heart damage, and cause skin diseases.
- Harmful substances can also have adverse effects on the respiratory and reproductive systems and lead to cancerous changes. Consumption of plants growing on the contaminated soils, and products made from them, may risk the above-mentioned health effects.
- Do not dispose of the device in the municipal waste container!!! Service: If you wish to purchase spare parts or report any complaints, please contact directly with the seller who issued the receipt directly.
Customer Support
- Address: Lyoner Str. 36 60528 Frankfurt am Main
- Tel:+49 69 310 900 66
- Website: www.ronixtools.com
FAQs
Q: What is the power rating and tank capacity of this model?
With its powerful 1400W motor and 30-liter stainless-steel tank, the Ronix 1231 provides strong suction and sufficient capacity for heavy cleaning tasks.
Q: Can I use the Ronix 1231 for both wet and dry cleaning?
Indeed. The Ronix 1231 is capable of handling both dry dust and liquid spills because of its dual functionality. Make sure you always install the appropriate filter type for the cleaning mode (dust filter for dry usage, foam filter for wet use).
Q: Can the Ronix 1231 pick up hot ashes or flammable materials?
No. Hot ashes, burning rubbish, and flammable substances like petrol, solvents, or oil-based paints should never be picked up with a hoover. By doing this, the unit could catch fire or sustain irreversible damage.
Q: Can I use the vacuum cleaner without the dust bag?
It is strongly advised to use a cloth filter or dust bag for dry cleaning in order to enhance dust collection and safeguard the motor. Use just the foam filter and take out the dust bag for wet cleaning.
Q: What is the maximum liquid capacity of the tank?
To avoid overflow, the maximum liquid level should not be more than 15 litres. When the liquid limit is reached, the float valve will automatically cut off the suction; empty the tank right away before continuing.
Q: Can I use the Ronix 1231 for fine dust (e.g., cement or drywall)?
Yes, however, to efficiently capture tiny particles, you need to utilise a HEPA or cartridge filter. A clogged filter can impair suction; therefore, avoid using the hoover on ultra-fine dust for extended periods of time without cleaning the filter.


















1 Comment
Pingback: Ronix 1250 Carpet Vacuum Cleaner User Manual | Safety Guide