Dometic P030 Magnetic-Drive Centrifugal Pump

Safety instructions
- Use only Dometic replacement parts and components that are specifically approved for use with the product.
- Avoid improper installation, change, alteration, service, or maintenance of the product.
- Electrical installation must be done by a qualified person only.
- Service and maintenance must be done by a qualified service person only.
- Do not change this product in any way. Modification can be extremely hazardous.
- Before attempting to make any electrical connections, ensure the electrical power is off and the water valves are completely closed.
- Secure and seal all wire connections to protect from arcing.
- Do not pump flammable or combustible liquids.
- Do not perform service or maintenance when the pumping system is pressurized.
- Do not operate the pump beyond the pressure or temperature limits.
- Do not allow severe temperature changes to occur in a short time period within the pumping system.
- Do not continue to operate the pumping system when a leak is detected.
- Do not touch the rotating components while the pump is in operation.
- The pump must be located in an inaccessible location to prevent accidental contact.
- Do not touch the surface of the pump during operation or before cool down.
- Follow proper procedures for draining and decontaminating the pump before maintenance.
- Clean the pump regularly to prevent dust buildup.
- Use a power monitor for pumps to stop the pump and prevent damage if the pump should run dry.
Explanation of Symbols
A signal word will identify safety messages and property damage messages, and will also indicate the degree or level of hazard seriousness.
- Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
- Indicates a situation that, if not avoided, can result in property damage.
Supplemental Directives
To reduce the risk of accidents and injuries, please observe the following directives before proceeding to install or operate this appliance:
- Read and follow all safety information and instructions.
- Read and understand these instructions before installing or operating this product.
- The installation must comply with all applicable local or national codes, including the latest edition of the following standards:
U.S.A.
- ANSI/NFPA 70, National Electrical Code (NEC)
- American Boat and Yacht Council (ABYC)
Canada
- CSA C22.1, Parts l & ll, Canadian Electrical Code
Intended use
The magnetic-drive centrifugal pumps (also referred to as the “pump” or the “product”) are marine grade, intended for use with leisure boats and marine applications with sea or non-potable water.
This product is only suitable for the intended purpose and application in accordance with these instructions. This manual provides information that is necessary for the proper installation and/or operation of the product.
Poor installation and/or improper operation or maintenance will result in unsatisfactory performance and a possible failure. The manufacturer accepts no liability for any injury or damage to the product resulting from:
- Incorrect installation, assembly, or connection, including excess voltage
- Incorrect maintenance or use of spare parts other than the original spare parts provided by the manufacturer
- Alterations to the product without express permission from the manufacturer
- Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product specifications
Target Group
The mechanical and electrical installation and setup of the device must be performed by a qualified technician who has demonstrated skill and knowledge related to the construction and operation of marine equipment and installations, and who is familiar with the applicable regulations of the country in which the equipment is to be installed and/or used, and has received safety training to identify and avoid the hazards involved.
Warranty
Refer to the sections below for information about warranty and warranty support in the US, Canada, and all other regions.
Disposal
Place the packaging material in the appropriate recycling waste bins, wherever possible. Consult a local recycling center or specialist dealer for details about how to DOMETIC SB27150 90 Degree Bezel Kit Installation dispose of the product in accordance with the applicable disposal regulations.
Customer Service
SPAIN
- Address: Dometic Spain S.L. Avda. Sierra del Guadarrama, 16 E-28691 Villanueva de la Cañada Madrid
- Call: 8 +34 900 100 245.
- Email: info@dometic.es
GERMANY
- Address: Dometic WAECO International GmbH Hollefeldstraße 63 • D-48282 Emsdetten
- Call: 9 +49 (0) 2572 879-195
- Email: info@dometic-waeco.de
FRANCE
- Address: Dometic SAS ZA du Pré de la Dame Jeanne B.P. 5 F-60128 Plailly
- Call: +33 344633518
- Email: vehiculesdeloisirs@dometic.fr
AUSTRALIA
- Address: Dometic Australia Pty. Ltd. 1 John Duncan Court • Varsity Lakes QLD 4227
- Call: 8 +61 7 55076001|
- Email: sales@dometic-waeco.com.au
FAQs
What is the Dometic P030 Magnetic-Drive Centrifugal Pump used for?
The P030 is a magnetically driven centrifugal pump with great efficiency that is mostly used for coolant or water circulation in industrial, marine, or recreational fluid systems.
What is a “magnetic-drive” pump, and why is it beneficial?
A magnetic-drive pump does not require a shaft seal since it uses a magnetic coupling between the motor and impeller. This design enables low-maintenance operation, minimises wear, and stops leaks.
What type of fluids can the P030 handle?
Freshwater, coolant mixtures, and light industrial fluids are examples of non-flammable, non-corrosive fluids for which the pump is intended. It is not appropriate for use with highly corrosive chemicals, petrol, or diesel.
Can the P030 run dry?
No, the pump does not prime itself, and it should never be left dry since this can harm the internal parts and impeller.
Is the pump submersible?
It is not true that the P030 is a submersible pump. It needs to have inlet/outlet ports to connect to fluid lines and be placed in a dry, well-ventilated environment.
What is the recommended power source?
Depending on the model, the P030 can run on either DC or AC power. Before installing, check your user handbook for the voltage and current requirements.
How should the pump be mounted?
In order to encourage gravity-assisted priming and flow, it should be positioned horizontally on a sturdy surface, preferably below the fluid level.
Does the pump require regular maintenance?
It needs very little upkeep. Check for obstructions, mineral accumulation, and tighten fittings on a regular basis. The magnetic drive technology lessens bearing and seal wear.