Orbegozo IM TES 3650 Wrist Blood Pressure Monitor

Introductions
- Thank you for choosing a blood pressure monitor ORBEGOZO.
- The unit uses the oscilloscope method of blood pressure measurement. It means the unit detects the
movement of your blood through your brachial artery and converts your blood pressure into a digital
reading. The unit is simple to use because a stethoscope is not needed while using an oscilloscope
monitor. - The unit stores automatically 60 sets of measurement values for each user (2×60). You can read the
stored data conveniently by pressing the memory button. - The unit comes with the following components: main unit, arm cuff, and instruction manual.
Symbols

Know Your Product



Battery Installation/Replacement
- Remove the battery cover from the battery compartment.

- Install 2 AAA-size batteries so the + (positive) and – (negative) polarities match the polarities of the
battery compartment as indicated.
- Replace the battery cover.

Adjusting Settings
Set the year
All information will appear when the batteries are installed for the first time. After 2 seconds, the year flashes.
- Press the “MEM” button to increase by one year.
- Press the “SET” button to decrease one year.
- Long-press the button and the value quickly changes.
The year can be set between 2011 and 2030, and it will return to 2011 when the display of years up to 2030.
Date and time
Press the “MEM” button to change the month and press the “SET” button, and continue with the next step. Then set the day, the time, and the minute by using the same method. Continue with step 3. 
To set the unit
- Then press the “MEM” button again to change the current unit.
- Press the “ START-STOP” button to save the current setting and turn off.

To set the user
- With the device turned off, the mark of a user will appear when pressing the SET button. Then press SET again to change the current user. Finally, press the START-STOP button to confirm the user and turn off.

Before Taking Measurements
Follow these instructions before taking a measurement:
- Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement.
- Stress raises blood pressure. Avoid taking measurements during stressful times.
- The cuff can be applied to your left or right wrist.
- Always measure your blood pressure on the same Arm.
- Measurements should be taken in a quiet place.
- Position the unit at heart level throughout the measurement.
- Remain still and do not talk during the measurement.
- Keep a record of your blood pressure and pulse readings for your physician.
- A single measurement does not provide an accurate indication of your true blood pressure.
- You need to take and record several readings over a period of time.
- Try to measure your blood pressure at the same time each day for consistency.
- Wait 30-60 seconds between measurements.
- The wait time allows the arteries to return to their condition before taking the blood pressure measurement.
- You may need to increase the wait time depending on your physiological characteristics.
Way of Measurement
- Remove all clothes from your arm, allowing the cuff to fit directly on the skin.

- Wrap the cuff tightly around your wrist, binding the Velcro strip.

- Sit in a chair with your feet flat on the floor.

Take A measurement
- Press the START-STOP button. All display symbols appear on the screen. The cuff starts to inflate automatically.
- Inflation stops automatically, and the measurement is started. The heartbeat symbol flashes once a pulse is detected.

- The blood pressure and pulse rate are displayed when the measurement is completed. The cuff is deflated automatically, and all of the measurement results are stored in the memory with date and time. The “IHB” symbol will be displayed if a regular heartbeat is detected.

- Press the “START-STOP” button to turn off the unit. The unit will automatically turn off after 2 minutes if you have forgotten to turn it off.

Use the Memory Function
- To read the average value
Press the “MEM” button. The average value symbol will display.
- To read the measurement value
Press the “MEM” button to view the latest measurement value with the measuring date and time. Press the “SET” button to view the oldest measurement value with the measuring date and time.
- To delete the memory value
- In the memory reading mode, press the “MEM” button for 4-6 seconds the unit will display.
- Press the “MEM” button again, and the LCD will display.
- If you are sure all the data of the corresponding user can be deleted, press the “START-STOP” button. All the corresponding user’s data will be deleted, and the unit will turn off.

Irregular Heartbeat Symbol
When the unit detects an irregular rhythm two or more times during the measurement, the irregular heartbeat Symbol will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster than the average rhythm detected while the monitor is measuring the systolic blood pressure and the diastolic blood pressure.
If the Irregular Heartbeat Symbol (IHB) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
Blood Pressure
Blood Circulation
The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure
exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the
blood pressure produced by the contraction of Orbegozo Wrist Blood Pressure Monitor the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle.
Health and Blood Pressure
The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat, and high levels of cholesterol (LDL), which sticks to the inside of blood vessels, reduce the elasticity of these vessels. Hypertension accelerates arterial sclerosis, which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons, it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute throughout the day. Therefore, it is essential to take regular measurements to help you identify an average blood pressure.
Classification of blood pressure
After each measurement is completed, the LCD will show your position automatically on the six
segments of the bar indicator that correspond to the World Health Organisation (WHO) Blood Pressure
Indicator. 
Symptoms of High Blood Pressure
High blood pressure can go unnoticed for a long time, since it does not cause noticeable symptoms. The
The following are all possible causes of abnormally high blood pressure:
- Overweight
- High cholesterol level
- Smoking
- Excessive alcohol consumption
- Stress and emotional upset
- Excessive consumption of salt
- Lack of physical exercise
- Genetic/hereditary predisposition
- Underlying illnesses, such as kidney disorders or endocrine disturbance
Treatment of high blood pressure
If your blood pressure reaches upper values of 140-160 mmHg and lower values of 90-95 mmHg in repeated
measurements over several days, you should consult your doctor for a detailed medical examination. You can
Assist the treatment prescribed by your doctor in the following ways:
- Lose weight and lower your cholesterol level
- Reduce the consumption of alcohol and salt
- Stop smoking
- Take regular exercise
- Monitor your blood pressure
Error Indication
Eliminate Fault

Cleaning & Maintenance
- Do not disassemble the unit
- Do not fold the cuff or immerse it in water
- Do not use volatile liquids to clean the main unit
- Do not use petrol, thinners, or similar Orbegozo Wrist Blood Pressure Monitor solvents to clean the cuff
- Do not subject the unit to strong shocks or vibrations
- Do not subject the main unit and the cuff to extreme temperatures, humidity, moisture, or direct sunlight.
- Do not carry out repairs of any kind yourself.
- If a defect occurs, please contact your distributor.
- If needed, please use ultraviolet radiation of disinfection.
- The unit should be cleaned with a soft, dry cloth.
- Use a soft, moistened cloth and soap to clean the arm cuff
- Substitution of a cuff different from that supplied might result in measurement error.

Specifications
Indicator for Use Statement
Please follow local ordinances or regulations for disposal.
- Applied part: cuff
- Protection class: internally powered equipment.
- Applied part type: type BF.
- Moisture protection: IPX0, continue operation.
- Altitude: <2000 m.
- Overvoltage: II
- Pollution degree: 2
- The unit might not meet its performance specifications if stored or used outside the following specified temperature and humidity ranges.
- The unit satisfies the requirements of IEC60601-1 Medical electrical equipment; IEC60601-1-2:2007: Electromagnetic compatibility-Requirements and tests; EN1060-1; Non-invasive sphy gmomanometers-Part
- requirements and test methods for non-automated measurement type; EN1060-
- Non-invasive sphygmomanometers – Part
- Supplementary requirements for electro-mechanical blood pressure measuring systems.
Guidance and Manufacturer’s Declaration
Electromagnetic Immunity
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the Digital Blood Pressure Monitor should ensure that it is used in such an environment.
- Over the frequency range kHz Ko 80MHz, field strengths should be less than 3V/m.
- Recommended separation distances between portable and mobile RF communications equipment and the Digital Blood Pressure Monitor.
- The customer or the user of the Digital Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Digital Blood Pressure Monitor, as recommended below, according to the maximum output power of the communications equipment.

Disposal of old electrical appliances
Consumers should contact their local authority or retailer for information concerning the correct disposal of their old appliance.
DECLARATION OF CONFORMITY: This device complies with the requirements of the Low Voltage Directive
2006/95/EC and the requirements of the EMC directive 2004/108/EC.
Customer Support
- Website: https://orbegozo.com/
- Ph: +34 943513492
FAQs
Q: What is the Orbegozo IM TES 3650 Wrist Blood Pressure Monitor?
For quick, precise, and portable blood pressure and pulse readings at home or on the go, the Orbegozo IM TES 3650 is a small, automatic wrist blood pressure monitor. It retains several readings for convenient tracking and employs cutting-edge oscillometric technology to deliver accurate results.
Q: My readings vary from day to day—is that normal?
Indeed. Throughout the day, blood pressure normally varies as a result of stress, activity, and nutrition. A clearer picture of your general blood pressure trends can be obtained by regularly checking your blood pressure at comparable periods throughout the day.
Q: How many readings can the monitor store?
Up to 120 readings can be stored by the IM TES 3650 (60 per user if dual memory mode is enabled). The oldest records are automatically replaced whenever they are full.
Q: Can more than one person use the device?
Yes, provided that dual-user memory is supported by your model. Before beginning a reading, hit the User button (U) to switch between User 1 and User 2.
Q: What type of batteries does it use?
Two AAA alkaline batteries are required for the Orbegozo IM TES 3650. When the screen displays the low battery symbol, replace both at once.
Q: Can I use rechargeable batteries?
Yes, but for the best results and longer battery life, regular alkaline batteries are advised. Shorter running times between charges are possible with rechargeable batteries.
Q: Can I use this monitor with a pacemaker or implanted medical device?
Before using any automated blood pressure monitor, speak with your healthcare practitioner if you have a pacemaker, defibrillator, or other similar device.