    Home » Renzor OPT-GC Gas Conversion Parts Instruction Manual
    Reznor

    Renzor OPT-GC Gas Conversion Parts Instruction Manual

    By Gabriel SmithSeptember 15, 2025Updated:December 11, 2025No Comments12 Mins Read
    Facebook Twitter Pinterest LinkedIn Tumblr WhatsApp Telegram Email
    Renzor-OPT-GC-Gas-Conversion-Parts-Featured
    Share
    Facebook Twitter LinkedIn Pinterest Email

    Renzor-logo

    Renzor OPT-GC Gas Conversion Parts

    Renzor-OPT-GC-Gas-Conversion-Parts-Product

    Safety Instructions

    • A caution statement describes a potentially hazardous situation that, if not avoided, can result in minor or moderate personal injury and/or property damage.
    • A note provides important information that should not be ignored.
    • Gas conversion should be made only by a qualified service technician.
    • Improper conversion will result in severe personal injury or death.
    • The Manufacturer will not accept responsibility or liability as a result of improper gas conversion.
    • Improper selection or servicing could result in death, severe personal injury, and/or property damage.
    • This instruction sheet includes parts and instructions for several models.
    • It applies only to the models listed on the front page and requires the selection of individual parts.
    • If your model is listed, contact your distributor to obtain a kit designed specifically for your application.
    • If your heater model is not listed in either place, conversion parts are not available.

    Model Number

    The identifying model number can be found on the heater rating plate. The rating plate identifies only original equipment, so also check the actual gas valve label and look for any gas or ignition conversion labels. When converting fuels, you must have the complete heater model number. Refer to Table 1 to decode a heater model number.

    Table. Decoding Heater Model Numbers
    Model No. Model Size Series No. Suffix
    RG 200-8-MB RG 200 8 MB (mechanical modulation)

    Selecting Parts

    If the unit being converted has multiple furnace sections, order all parts for each furnace. Required conversion parts for models without conversion kits must be selected individually. The following parts are required for gas conversion:

    • Select Spring Regulator Kit or Replacement Valve section)
    • Select Natural Gas or Propane Gas Pilot Orifice section)
    • Select the Main Burner Orifices section.
    • Burner air shutters (required only for conversion from natural gas to propane)
    • Conversion Disk or Conversion Label Selection section)
    • Ignition controller (required only for conversion from natural gas to propane with spark pilot). Select Ignition Controller (for Natural Gas to Propane Conversion with Spark Pilot) section)
    • Select the Carryover Parts section. Select conversion parts by the following steps.
    Select Spring Regulator Kit or Replacement Valve
    Table. Single-Stage Gas Valves that Require Replacement Gas Valves
    Propane to Natural Gas Conversion Natural Gas to Propane Conversion*
    Original Gas Valve PN (Manufacturer’s PN) Replacement Gas Valve PN (Manufacturer’s PN) Original Gas Valve PN (Manufacturer’s PN) Replacement Gas Valve PN (Manufacturer’s PN)
    Units with Spark Pilot
    89462

    (Robertshaw #DER7100)

    96307

    (Honeywell #VR8204M1000)

    89461

    (Robertshaw #DER7100)

    96310

    (Honeywell #VR8204M1018)

    Units with Direct Ignition
    147134

    (Robertshaw #7222DERLP)

    260604

    (Honeywell #VR8215S1263)

    147133

    (Robertshaw #7222DER)

    260606

    (Honeywell #VR8215S5215)

    Table. Two-Stage Gas Valves that Require Replacement
    Propane to Natural Gas Conversion Natural Gas to Propane Conversion1
    Original Gas Valve PN (Manufacturer’s PN) Unit Size
    075–250 300–400 075–400
    Replacement Gas Valve PN (Manufacturer’s PN) Original Gas Valve PN (Manufacturer’s PN) Replacement Gas Valve

    PN

    (Manufacturer’s PN)

    Units with Match-Lit Pilot
    62967

    (Honeywell #V850A)

     

    96306

    (Honeywell #V850E)

     

    115352

    (White-Rodgers #36C41)

    115351

    (White-Rodgers #36C40, 3/4-inch)2

    115351

    (White-Rodgers #36C40, 3/4-inch)2

    62966

    (Honeywell #V850A)

     

    96304

    (Honeywell #V850E)3

     

    96305

    (Honeywell #V850E)3

     

    115351

    (White-Rodgers #36C40)

    115352

    (White-Rodgers #36C41, 3/4-inch)2

    Units with Spark Pilot
    87431

    (White-Rodgers #36D13)

     

    96312

    (White-Rodgers #36D13)

     

    177395

    (Honeywell #VR8204)

     

    177398

    (Honeywell #VR8304)

    177396

    (Honeywell #VR8204Q, 1/2-inch)4

    177397

    (Honeywell #VR8304Q,

    3/4-inch)2,4

    87430

    (White-Rodgers #36D13)

     

    87432

    (White-Rodgers #36D13)

     

    177396

    (Honeywell #VR8204)

     

    177397

    (Honeywell #VR8304)

    177398

    (Honeywell #VR8304Q,

    1/2 × 3/4-inch)4,5,6

    Select Ignition Controller (for Natural Gas to Propane Conversion with Spark Pilot)

    When converting indoor units with a spark pilot (indoor and outdoor in Canada) to propane, the ignition controller must have a 100% lockout. Refer to the flowchart shown in Figure 1 for ignition controller selection.

    Select Carryover Parts

    Carryover Lighter Tube System Determination

    • Burner Rack Without Carryover Lighter Tube
    • Burner Rack with Lighter Tube Carryover System Without Regulator (Used with Natural Gas)
    • Burner Rack with Lighter Tube Carryover System with Regulator (Used with Propane Gas) Renzor-OPT-GC-Gas-Conversion-Parts-fig-2
    Carryover Lighter Tube System for Propane to Natural Gas Conversion

    For propane to natural gas conversions, order the carryover lighter tube orifice listed in Table 10 (if required) plus the following:

    • One (1) elbow, brass (PN 93388)
    • One (1) tube, carryover, 8-3/4 (PN 93389)
    • One (1) fitting, compression (PN 9664)

    Models (H)RP, (H)CRP, (H)RPB, (H)CRPB; Models (H)RPV, (H)CRPV Series 6, 7, and 8; Models SC, SCA, SCB, SCE Series 6; Models (H)X, (H)XE, PAK Series 8; and Model PGBL do not require a carryover orifice change when converting from either propane to natural gas or natural gas to propane. When converting to natural gas, remove the regulated carryover lighter tube (see Figure 2) and install the natural gas carryover tube using the original (propane) carryover orifice.

    Select Carryover Lighter Tube System for Natural Gas to Propane Conversion

    For natural gas to propane conversions, order the carryover lighter tube orifice system parts listed in Table 11 (if required) plus one (1) regulated carryover assembly (PN 100712) as shown in Figure 3. The regulator is factory-set at 1 inch of pressure at the outlet. DO NOT CHANGE PRESSURE SETTING. For units with multiple furnaces, order parts for each furnace.

    (H)SC, SCA, SCB, SCE series 6; (H)X, (H)XE, PAK series 8; and PGBL do not have a lighter tube carryover system on a natural gas burner. When converting to propane, remove the burner and remove the factory-installed flash carryover from the orifice end of the burner rack—do not remove the flash carryover from the other end of the burner rack. Order the drip shield and carryover lighter tube listed by PN and install as shown in Figure 4.

    Renzor-OPT-GC-Gas-Conversion-Parts-fig-3

    • (H)RP, (H)CRP, (H)RPB, (H)CRPB, (H)RPV, (H)CRPV series 6, 7, and 8 do not require a carryover orifice change when converting from either propane to natural gas or natural gas to propane. When converting to propane, they do require the addition of the regulated carryover assembly (PN 100712) using the original (natural) carryover orifice.
    • LG = length in inches.Renzor-OPT-GC-Gas-Conversion-Parts-fig-4

    Installation of Gas Conversion Parts

    1. SC series burner racks include a burner rack skirt that is used only on separated-combustion models.)Renzor-OPT-GC-Gas-Conversion-Parts-fig-5
      • Remove the side panel from the unit.
    2. Replace burner orifices.
        • Remove two screws that secure the bottom of the burner rack assembly.
    3. Replace the pilot orifice.
      • Remove screws and lift out the pilot burner.
    4. Install valve regulator spring kit.
      • Follow the valve manufacturer’s installation instructions that are included with the spring kit.

    Renzor-OPT-GC-Gas-Conversion-Parts-fig-6

    • Remove 1/4-inch sheet metal screws in manifold mounting angles and remove the manifold assembly.

    • Remove 1/4-inch sheet metal manifold bracket screws and remove the manifold assembly.
    • If orifice change is required, insert the replacement orifice.
    • Reverse the above procedures to reassemble the heater.
    • Turn ON electricity and gas. Relight the heater.

    Flame and Pressure Adjustments

    When installation of gas conversion parts is complete, adjust the pilot lame and the manifold pressure as follows.

    Adjust Pilot Flame

    Refer to Figure 11, which shows the desired pilot flame height, and adjust the pilot flame as follows.

    1. Loosen and remove the pilot adjustment cover screw on the valve.
    2. Turn the inner adjustment screw counterclockwise to increase flame or clockwise to decrease flame.
    3. Install and tighten the pilot adjustment cover screw on the valve.
    Adjust Manifold Gas Pressure

    For Natural Gas

    High fire manifold pressure is regulated by the combination valve to 3.5 IN WC. Inlet pressure to
    The valve must be a minimum of 5 IN WC or as noted on the Renzor OPT-GC Gas Conversion Parts rating plate and a maximum of 14 IN WC.

    For Propane

    The regulator in the valve must be adjusted to provide a manifold pressure of 10 IN WC. Inlet pressure to the valve must be a minimum of 11 IN WC and a maximum of 14 IN WC. Measure and adjust (if required) the manifold gas pressure as follows:

    • Position the manual valve (on the combination valve) to prevent flow to the main burner.
    • Connect the manometer to the 1/8-inch pipe outlet pressure tap in the valve.
    • Open the valve and operate the heater to measure the manifold gas pressure.
    • If the manometer indicates that the manifold gas pressure needs adjustment, set the correct pressure by turning the regulator screw on the valve Renzor OPT-GC Gas Conversion Parts IN (clockwise) to increase pressure or OUT (counterclockwise) to decrease pressure.
    • Disconnect the manometer from the 1/8-inch pipe Renzor OPT-GC Gas Conversion Parts outlet pressure tap in the valve.

    Gas Conversion of Direct-Fired Furnaces

    Perform gas conversion of direct-fired furnaces as follows:

    • Shut OFF the gas at the main manual shut-off. Turn the electricity off at the disconnect switch.
    • Open the burner section door panel.
    • For ADF/ADFH models, replace the pilot gas regulator. Refer to Figure 12 to select a replacement pilot gas regulator.
    • For the ADF/ADFH model that does not have electronic Renzor OPT-GC Gas Conversion Parts modulation gas controls, follow the valve manufacturer’s instructions to install the spring regulator kit or to install the replacement valve.
    • Locate the pressure regulator and remove the cap (see Figure 13) and the adjustment screw from the pressure regulator. The regulator spring is now visible.
    Table 12. Regulator Springs for Direct-Fired Models with Electronic Modulation Gas Control System
    Spring PN Spring Color Gas Type Pressure Range Maxitrol Model
    97351 Orange Natural 4–8 IN WC R5310-48
    91787 Brown Propane 1–3.5IN WC R5310-13
    97196 Cadmium-Plated Natural 3–6 IN WC R5310-36
    • Remove the regulator spring.
    • Refer to Table 12 to select the replacement regulator Renzor OPT-GC Gas Conversion Parts spring.
    • Install the replacement regulator spring and replace the adjustment screw.
    • Measure gas pressure at the burner and adjust the pressure to meet application requirements.
    • Replace the cap on the pressure regulator.
    • Turn ON the electricity at the disconnect switch.
    • Turn ON the gas at the main manual shutoff.
    • Replace the burner section door panel. Unit is now Renzor OPT-GC Gas Conversion Parts operational from the system switch on the remote console.

    Startup Checklist

    Check for safe and proper operation of the heater as follows:

    • Operate the heater for at least one cycle
    • Cautiously observe the main burners for complete flame carryover.
    • Flame must be present on the full length of each burner.
    • Adjust air shutters (if used) after the heater has been in operation for 15 minutes.
    • Turn adjustment screws to close air shutters no more than necessary to eliminate any problem condition.
    • Observe flame for yellow tipping. A limited Gas Conversion and Ignition Conversion Kitsmount Renzor OPT-GC Gas Conversion Parts of yellow tipping is permissible for propane.
    • Complete information is required on the Renzor OPT-GC Gas Conversion Parts conversion label. Attach the disk to the heater near the gas valve.

    Gas Conversion and Ignition Conversion Kits

    Currently-Manufactured Models with Gas Conversion Kits
    Model(s) Applicable Technical Manual* Application
    Form PN
    B, F CP-F/B-GC 99279 All sizes
    CAUA CP-CAUA-GC 170635
    LDAP CP-LDAP-GC 208881
    PDH, RDH, RHH, SDH, SHH CP-PREEVA-GC 212063 Units with single- or two-stage gas controls
    UDAP, UDAS, UDBP, UDBS, APD CP-UD&APD Series GC 197209 All sizes
    UEAS I-UEAS 221232
    VR CP-VR-GC 205510
    *Technical manual lists conversion kit PNs by size. Contact your Distributor for copies of the technical manuals listed in this table.

    Ignition conversion kits are NOT gas conversion kits.

    Ignition Conversion Kits to Convert from Match-Lit Pilot to Spark Pilot for Models F and B Manufactured Before AUG 2008
    Model F or B Gas Ignition Conversion Kit Technical

    Manual Form

    (PN)

    Description Model PN
    F/B 25-165 Natural Spark-ignited, intermittent safety pilot without lockout UTC Model 1003-638A (PN 257009) 100525 CP-F/B IGN (100550)
    F/B 200-250 100526
    F 300-400, B 300 100527
    B 400 102348
    F/B 25-165 Natural Spark-ignited, intermittent safety pilot with lockout UTC Model 1003-514 (PN 257010)* 100528
    F/B 200-250 100529
    F 300-400, B 300 100530
    B 400 102349
    F/B 25-200 Propane 100531
    F 250-400, B 250-300 100532
    B 400 102350
    *Controller includes a terminal for connecting the vent damper.

    Limited Warranty

    Reznor LLC warrants to the original owner-user that this product will be free from defects in material and workmanship. This warranty is limited to twelve (12) months from the date of original installation, whether or not actual use begins on that date, or eighteen (18) months from the date of shipment, whichever occurs first.

    Manufacturer Replacement Parts Limited Warranty

    Reznor LLC warrants replacement parts for thirty (30) days after installation or thirteen (13) months from the date of shipment, whichever occurs first.

    Customer Support

    • Website: www.reznorhvac.com
    • Ph: 800-695-1901

    FAQs

    Q: What is the Renzor OPT-GC Gas Conversion Kit?

    The purpose of the Renzor OPT-GC kit is to change the type of gas that gas-powered appliances run on (for example, from natural gas to LPG or vice versa). It has all the parts that are required, including connectors, regulators, and orifices.

    Q: Which appliances are compatible with this kit?

    Gas stoves, ovens, grills, and certain other heating appliances are usually compatible with the kit. Prior to attempted conversion, always review the appliance’s specifications.

    Q: Is the installation of the kit safe for beginners?

    Because gas conversion includes handling dangerous fuel, the installation should only be done by a licensed technician or by people who are familiar with gas systems. Leaks, fires, and carbon monoxide dangers all arise from improper installation.

    Q: Can I convert the gas type myself?

    Yes, but only if you know how to handle gas connections and adhere to safety protocols. Speak with a certified gas technician if you’re unsure.

    Q: How do I know which parts to use for my appliance?

    Various connectors, regulators, and orifices are included in the package. To match the target gas type with the appliance model, use the instruction manual chart.

    Q: Can I convert appliances from LPG to natural gas?

    Indeed, both conversion orientations’ components are included in the package. To make sure the right parts are utilised, always refer to the handbook.

    Q: Will conversion affect appliance performance?

    The appliance should function as intended when the right parts are used. Poor combustion, yellow flames, or decreased efficiency can arise from using the wrong or defective parts.

    Gas Conversion Kit Renzor OPT-GC Gas Adapter Parts OPT-GC Gas Parts Renzor Gas Conversion Parts Renzor OPT-GC Renzor OPT-GC Replacement
    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Gabriel Smith

    Related Posts

    DOMO DO8140 Free Standing Ventilator Fan Instruction Manual

    September 15, 2025

    Renzor HEEDU Replacement Pressure Switch Kit Installation

    September 11, 2025

    Renzor LDAP Downturn Nozzle Kit Installation Instruction

    September 11, 2025

    Renzor CAUA Ignition Controller Replacement Kit Installation

    September 11, 2025

    Renzor RP-PRESS-SW Pressure Switch Kit Installation Guide

    September 11, 2025

    Renzor RPV, SCA, Venter Motor Replacement Kit Installation

    September 11, 2025
    Add A Comment

    Comments are closed.

    Don't Miss
    Other

    What Is A Mirrorless Cameras

    April 13, 2026

    Introduction Mirrorless cameras are really cool because they do not have a mirror and optical…

    Camera a7S SONY

    April 13, 2026

    NEBULA D2040R Wireless Satellite Speaker Instruction Guide

    April 13, 2026

    AURZEN BOOM mini 4 Inch 1 Smart Projector Instruction Guide

    April 13, 2026
    Stay In Touch
    • Facebook
    • Twitter
    • Pinterest
    • Instagram
    • YouTube
    • Vimeo

    Subscribe to Updates

    Subscribe to Updates

    Follow us

    Facebook X-twitter Instagram Pinterest

    © 2025 All rights reserved Onyx Guide.