BROMIC 3735204-NR Underbench Fridge
Safety Instructions
- Use this appliance only as described in this manual.
- Any other use not recommended by the manufacturer may cause fire, electric shock, or injury.
- The manufacturer is not responsible for any damage that could happen from improper use.
- Check the appliance for damage.
- Do not operate a damaged unit.
- Check for damage to the appliance regularly.
- Keep packaging material out of each child’s reach.
- Children should be carefully supervised to ensure that they do not play with the appliance.
- Do not attempt to alter the appliance in any manner.
- Please pay attention to the maximum load limit when filling the shelves.
- All work on electrical equipment must be carried out by a qualified and licensed technician only.
- Do not perform maintenance until the appliance has been turned off and the power disconnected.
- Do not operate the appliance with panels, covers, or guards removed.
- Keep the air intake and outlets free of obstructions.
- Do not use the appliance outdoors.
- If the appliance has not been used or will not be used for a long period, disconnect the power supply.
- The refrigerant used in all appliances covered by this manual is flammable.
Installation
- Do not install the cabinet outdoors.
- Locate the appliance in a dry and well-ventilated place.
- The unit must be positioned on a level surface.
- Do not install in the vicinity of heating radiators or other heat sources.
- Do not install the appliance where it is exposed to direct sunlight.
- Do not install the appliance where it is exposed to warm draughts or open doors.
- Keep the air intake and outlets free of obstructions.
- Adequate allowance should be made for door openings.
Ventilation
- Allow 150mm clearance between walls, ceiling, and BROMIC 3735204-NR Underbench Fridge the appliance.
- Ensure that the condenser fan is free to take in ambient air from the room.
- Ensure adherence to minimum clearances and maximum ambient temperature for optimal performance and reliability.
Power Supply
- The appliance must not be plugged into a multiple-outlet power board.
- The appliance is supplied with a flexible power cord fitted with a 3-pin plug.
- The socket used must be properly earthed and fuse/RCD protected.
- See the rating label inside the cabinet for supply voltage, frequency, and current draw.
- Power cable should not be placed next to a heat source such as a room heater or other electrical appliance.
- Do not turn off the power before consulting the person responsible.
- Mark the power source clearly, so the refrigerator is not unplugged or turned off accidentally.
Before Operating
- Avoid tilting or transporting the appliance in a horizontal position. If the appliance were to be tilted, it must be left to stand in an upright position and not plugged in for at least 6 hours.
- Remove all the packaging material before using the appliance.
- Start the appliance only if it has been installed as described.
Operation
Start-up
- Connect the appliance to the mains power supply and turn on the main switch by flipping it upward.
- The LED indicates that the efrigeration circuit is operating.
- During the start-up delay (3 minutes), the LED is flashing.
- The LED indicates that the refrigeration circuit is defrosting.
Setting the temperature
- Press the button for more than 3 seconds.
- Press or arrow key within 10 seconds to adjust the set point.
- Press the key again or wait 10 seconds.
Storagae
Start-up
- Clean the interior surface with a soft cloth and warm water before loading.
- Ensure there is free circulation of air between the products.
- Do not block the evaporator fan.
- Do not overstock the refrigerator.
- Keep refrigerator door openings to a minimum.
- Some products are sensitive to ultraviolet (UV) light. Please see the storage guidelines from the manufacturer before removing from packaging.
- The maximum recommended shelf load (for each shelf) is specified in section 3 (page 5) of this manual. Do not overstock.
Maintainance
- Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.
- Exposure to significant water ingress will void the warranty and cause potential safety issues.
Condenser Coil/FilterÂ
- A poorly maintained condenser coil can lead to failure of the unit and higher cabinet temperatures.
- Use caution while cleaning, as fins are sharp.
Cleaning the Cabinet
- Do not use any aggressive or abrasive cleaning agents.
- Never use a water hose or a high-pressure jet to clean.
- Do not use sharp or pointed objects for cleaning.
- Clean the inside and outside of the appliance with a clean, damp cloth or with a neutral cleanser.
- Dry all surfaces with a dry cloth.
Specifications
| Part Number | 3735213-NRÂ Â Â Â Â Â Â Â Â Â Â 3735204-NRÂ Â Â Â Â Â Â 3735211-NRÂ Â Â Â Â Â Â Â Â 3735206-NRÂ Â Â Â Â Â Â 3735212-NR | |||||
| External Dimension | Height, mm | 850Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 850Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 850Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 850Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 850 | ||||
| Width, mm | 1360Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 1360Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 1795Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 1795Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 2230 | |||||
| Depth, mm | 700Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 700Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 700Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 700Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 700 | |||||
| Net Capacity | Litres | 282Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 282Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 417Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 417Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 553 | ||||
| Net Weight | kg | 98Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 98Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 134Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 134Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 153 | ||||
| Air Circulation | Type | Forced                  Forced                 Forced                 Forced                 Forced | ||||
| Max Ambient | Temperature | 32°C                     38°C                    32°C                    38°C                    32°C | ||||
| Exterior | Material | Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel | ||||
| Electrical | Voltage, V a.c. | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 |
| Frequency, Hz | 50 | 50 | 50 | 50 | 50 | |
| Current, A | 2.0 | 2.0 | 2.0 | 2.0 | 2.7 | |
| Power, W | 275 | 275 | 275 | 275 | 398 | |
| Door | Solid/Glass | Glass | Solid | Glass | Solid | Glass |
| Type | Hinged | Hinged | Hinged | Hinged | Hinged | |
| Self-Closing | Yes | Yes | Yes | Yes | Yes | |
| Door Lock | No | No | No | No | No | |
| Shelves | Qty | (2+base)x2 | (2+base)x2 | (2+base)x3 | (2+base)x3 | (2+base)x4 |
| Weight Limit, kg | 20 | 20 | 20 | 20 | 20 | |
| Adjustable | Yes | Yes | Yes | Yes | Yes | |
| Refrigeration | Refrigerant | R600a | R600a | R600a | R600a | R290 |
| Charge, g | 120 | 120 | 120 | 120 | 125 | |
| Plug | Rating | 10A | 10A | 10A | 10A | 10A |
| Wheels | Type | Castors | Castors | Castors | Castors | Castors |
Troubleshooting
| Symptom | Possible Cause(s) | |
| The unit does not work | A. No power supply B. Main switch off | A. Check power supply. B. Turn on the main switch |
| Cabinet
Temperature Too High |
A.                  Ambient temperature too high
B.                  Inadequate ventilation C.                  Wall clearances below the minimum distance D.                 Dirty condenser coil and filter E.                  Ice build-up on evaporator coil |
A.                  Relocate unit
B.                  Keep ventilation slots free C.                  Adjust to minimum clearance D.                 Clean E.                  Check gaskets and set   temperature |
| Cabinet
Temperature Too Low |
A. Set the temperature too low | A. Adjust the set temperature |
| Water leak | A. Extreme operating condition | A. Relocate unit |
| Odour inside the cabinet | A. Cabinet dirty | A. Clean |
| Controller error code | A.  P1
B.  P2 C.  dA |
A.                  Room probe failure
B.                  Evaporator probe failureC. Door open or door switch failure |
| Noisy | A. Unlevel surface | A. Relocate unit |
Diposal
The refrigerant used and contained within a hermetically tight circuit is environmentally friendly and does not contain chlorine and has zero ODP.
- Before disposal, render it unserviceable by disconnecting the power plug and severing the power cable.
- Consult your local authorities or authorised dealers for details of collection and disposal facilities.
- Children are often unable to recognise the dangers associated with commercial refrigeration equipment.
- The refrigerant used in all appliances covered by this manual is flammable.
Warranty
Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.
Customer Support
North America
- Tel:Â (800) 301-1293
- Website:Â http://www.bromic.com
Australia
- Tel:Â 1300 276 642
- Website:Â http://www.bromic.com.au